Typ GSW 20A
(von..V auf.. V)
|
|
Einngangsspannung
|
Ausgangsspannung
|
Ausgangsstrom
|
|
•
220V / 24V
|
=
|
180...250V
DC
|
24V
DC +/-2% |
0,75A |
|
•
220V / 48V
|
=
|
180...250V
DC |
48V
DC +/-2% |
0,4A |
|
•
220V / 60V
|
=
|
180...250V
DC |
60V
DC +/-2% |
0,3A |
|
•
220V / 110V
|
=
|
180...250V
DC |
110V
DC +/-2% |
0,1A |
|
•
110V / 12V
|
=
|
75...140V
DC |
12V
DC +/-2% |
1A |
|
•
110V / 24V
|
=
|
75...140V
DC
|
24V
DC +/-2% |
0,75A |
|
•
110V / 60V
|
=
|
75...140V
DC |
60V
DC +/-2% |
0,3A |
|
•
110V / 110V
|
=
|
75...140V
DC |
110V
DC +/-2% |
0,1A |
|
•
60V /12V
|
=
|
40...75V
DC |
12V
DC +/-2% |
1A |
|
•
60V / 24V
|
=
|
40...75V
DC |
24V
DC +/-2% |
0,75A |
|
•
60V / 60V
|
=
|
54...72V
DC |
60V
DC +/-2% |
0,3A |
|
•
24V / 12V
|
=
|
18...32V
DC |
12V
DC +/-2% |
1A |
|
•
24V / 24V
|
=
|
18...32V
DC |
24V
DC +/-2% |
0,75A |
|
| • Taktfrequenz |
= |
ca. 50 kHz |
| • Elektronische
Strombegrenzung |
= |
ca. 1,2
facher Nennstrom |
| • Überspannungsbegrenzung |
= |
ca. 1,2 fache
Nennspannung |
| • Restwelligkeit |
= |
ca. 100mVss |
|
| • Einbaulage |
= |
beliebig |
| • Gewicht |
= |
0,3 kg |
| • Betriebsumgebungstemperatur |
= |
-20°C...+60°C
ohne Betauung |
| • Lagertemperatur |
= |
-20°C...+70°C
ohne Betauung |
| • Zulässige
relative Luftfeuchte |
= |
maximal 75%
im Jahresmittel (Gruppe F DIN 40040) |
| • Einschaltdauer |
= |
100% |
| • Schutzart |
= |
IP 40 |
| • Isolationsprüfung |
= |
2,5kV Luft-
und Kriechstrecke nach VDE 0110 Gruppe C |
|
Technische Änderungen und Irrtümer vorbehalten |
|